This comprehensive document offers vital information for the installation, operation, and maintenance of various process pumps, including the i-FRAME series. Carefully reading this guide is paramount to prevent personal injury, equipment damage, and warranty voidance. Additional documentation is available through your ITT representative.

Purpose of the Installation, Operation, and Maintenance Manual
The primary purpose of the Goulds Pumps 3196 i-FRAME Installation, Operation, and Maintenance Manual is to furnish users with all essential information required for the safe and efficient handling of these severe duty process pumps. This critical document specifically covers the installation, ongoing operation, and necessary maintenance procedures for models such as the 3196, CV 3196, HT 3196, LF 3196, NM 3196, 3198, and 3796. Its explicit aim is to guide personnel through every phase of the product lifecycle, from initial setup to routine servicing, ensuring optimal performance and longevity.

Furthermore, the manual serves as an indispensable safety resource. It is imperative that all users carefully read and understand its contents before installing and utilizing the product. Failure to meticulously observe the instructions outlined within can lead to severe consequences, including personal injury, significant property damage, product malfunction, and the potential voiding of the manufacturer’s warranty. The manual details various hazard levels and emphasizes user safety requirements, stressing the importance of adherence to prevent accidents and health problems. By providing clear guidelines, it empowers operators to mitigate risks associated with electrical installation and product handling, thereby promoting a secure working environment. This comprehensive guide ensures informed decision-making and proper interaction with the Goulds 3196 series pumps, safeguarding both equipment and personnel.
Accessing Goulds Pumps 3196 i-FRAME Manuals and Documentation

Users seeking comprehensive documentation for Goulds Pumps 3196 i-FRAME series, including the crucial Installation, Operation, and Maintenance Manual, have several convenient avenues. The primary resource, often readily available for free PDF download, provides detailed instructions essential for safe and efficient handling of these severe duty process pumps. Online platforms frequently host these manuals, allowing direct viewing and seamless downloading, such as the full 162-page Installation, Operation And Maintenance Manual specifically for the 3196 i-FRAME water pump. These digital resources often include complete tables of contents, facilitating easy navigation to specific sections like safety, installation procedures, or advanced troubleshooting. For supplementary or more specialized documentation, including other relevant manuals or specific certifications like CE, CE ATEX, or Chinese Certificates of Conformity, users are highly advised to contact their local ITT representative. When requesting technical information or ordering spare parts, it is absolutely imperative to specify the exact product type and identification code to ensure accurate and timely assistance. This ensures all necessary information, from a general overview to specific certifications and detailed troubleshooting guides, is readily obtainable for effective product management and compliance with operational standards, fostering optimal performance.

Goulds 3196 Product Description and Models
The Goulds 3196 series, including i-FRAME and NM 3196 models, represents horizontal, overhung, open impeller, centrifugal pumps. These ANSI B73.1 compliant units are engineered for severe corrosives, featuring diverse power ends and hydraulic sizes for industrial needs.
General Overview of the NM 3196 Centrifugal Pump
The NM 3196 centrifugal pump stands as a prime example of robust industrial pumping technology, meticulously designed for a multitude of demanding applications. Characterized by its horizontal, overhung, and open impeller configuration, this pump delivers reliable performance in challenging operational environments. Its construction from a specialized fiber-reinforced vinylester makes it exceptionally capable of handling severe corrosive media, commonly encountered in the chemical, mining, oil & gas, power generation, pulp and paper, and general industrial sectors. The pump strictly adheres to ANSI B73.1 standards, ensuring broad interchangeability and consistent engineering quality. Furthermore, the NM 3196 boasts significant versatility in its design, being built upon two distinct power ends and offering a selection of thirteen hydraulic sizes. This extensive range enables precise customization to meet specific flow and pressure requirements, optimizing system efficiency. As an integral part of Goulds Pumps’ distinguished product line, it embodies a legacy of innovation and quality in pump manufacturing.
ANSI B73.1 Compliance and Material Specifications
The Goulds 3196 series, including the NM 3196 centrifugal pump, strictly adheres to the rigorous ANSI B73.1 standard. This compliance ensures the pump meets industry-recognized dimensional, interchangeability, and performance specifications vital for chemical process services. Adherence to ANSI B73.1 simplifies system integration and routine maintenance. Material specifications are paramount for durability and safety in corrosive environments. The NM 3196, for instance, is constructed from fiber-reinforced vinylester. This advanced composite material offers exceptional resistance to severe corrosives, making it ideal for industries handling aggressive chemicals where metallic pumps would quickly degrade. The “MAT L. CONST.” field on the pump’s nameplate explicitly details the specific materials of construction for each unit. This clarity in material specification is crucial for matching the pump to the exact chemical compatibility requirements of the fluid being processed, thereby extending operational lifespan, minimizing downtime, and ensuring the safety of operations in demanding industrial settings.
Specific Goulds Models Covered by the Manual
The Goulds Pumps 3196 i-FRAME Installation, Operation, and Maintenance Manual is an essential resource, offering comprehensive instructions for various Goulds industrial process pumps. This crucial document details procedures for the foundational Goulds 3196 model, key in many crucial global industrial applications. Beyond the core 3196, the manual guides users on specialized derivatives, including the CV 3196, HT 3196, and LF 3196, each specifically designed for particular operational contexts and fluid handling. Furthermore, it covers the NM 3196, highlighting its adherence to ANSI B73.1 standards and robust construction from advanced materials like fiber-reinforced vinylester, suitable for challenging corrosive services. Importantly, the manual’s scope extends beyond the 3196 series, encompassing the distinct Goulds 3198 and 3796 pump models. This broad coverage ensures operators and maintenance personnel have a centralized, reliable reference for all installation, operation, and upkeep requirements across these vital Goulds pump configurations, promoting efficiency and operational safety.
Detailed Part Descriptions: Covers and Seal Chambers

The Goulds 3196 i-FRAME manual details critical pump components, focusing specifically on covers and seal chambers, vital for robust, leak-free operation, thereby ensuring consistent performance. The design incorporates a versatile standard stuffing box cover, engineered to readily accommodate either traditional packing arrangements or modern mechanical seals. This inherent adaptability allows flexible configuration to suit diverse application requirements. For the 3196 model, internal threads are meticulously sealed from the pumped liquid using a durable PTFE O-ring, significantly enhancing overall reliability and actively preventing fluid escape. This is especially crucial for pumps handling severe corrosives safely, efficiently over extended periods.
Furthermore, the manual elucidates advanced seal chamber designs, including the innovative BigBore and TaperBore PLUS configurations. These specialized seal chambers are precisely engineered with specific internal geometries to significantly improve mechanical seal performance and longevity. Such enhancements involve optimized flow patterns around seal faces, leading to superior heat dissipation and creating a stable, efficient operating environment for the seal. This detailed design attention ensures maximum operational efficiency and extended service life for the Goulds 3196 series, minimizing downtime and maintenance costs for industrial applications relying on precise sealing technology.

Safety, Warranty, and Compliance
This section emphasizes critical safety instructions to prevent injury and damage, outlining hazard levels and environmental requirements. It details product warranty processes and confirms compliance with essential CE, ATEX, and CSA certifications, ensuring safe, regulated operation.
Critical Safety Instructions and Hazard Levels
Adhering to the Goulds Pumps 3196 i-FRAME Manual’s safety instructions is paramount. Disregarding these guidelines risks severe personal injury, property damage, and warranty invalidation. Always read this manual thoroughly before installation, operation, or maintenance to comprehend all warnings.
The manual defines various hazard levels. A “DANGER” indicator highlights situations where failure to avoid results in death or serious injury. Understanding these distinctions is vital for preventing personal accidents, health problems, and product malfunctions. This structured safety approach ensures users know the risk severity, fostering a safer working environment.

Crucially, verify the pump’s code classifications are compatible with the intended installation environment. Operating in an unsuitable environment poses considerable hazards. If incompatibility is detected, immediately halt equipment operation and contact an authorized ITT representative. This provides essential guidance, preventing dangerous situations, and safeguarding personnel and the Goulds 3196 pump’s integrity.
Environmental and User Safety Requirements
Adhering to environmental and user safety protocols is crucial for the Goulds 3196 pump. If the product is contaminated by toxic chemicals or nuclear radiation, it must be properly decontaminated before any return to ITT. For electrical installation recycling, always consult your local electric utility to meet specific requirements, ensuring responsible disposal and environmental protection.
User safety mandates strict adherence to all manual instructions. Disregarding these can result in personal injury, property damage, and void the warranty. It is imperative to read this manual thoroughly before installation, operation, or maintenance. Furthermore, verify the pump’s code classifications align with the installation environment. Should incompatibilities arise, immediately cease operation and contact an ITT representative for guidance. For overhead installations, consider consulting a noise specialist and implement special precautions to mitigate noise transmission, thereby maintaining a safe and healthy working environment for all personnel near the equipment.
Product Warranty and Claim Procedures
Goulds Pumps, including the 3196 i-FRAME series, are recognized for their high quality, robust construction, and anticipated long operational life. These products are designed to deliver reliable performance across various industrial applications. However, should an issue arise that necessitates a warranty claim, specific procedures must be followed to ensure proper resolution. Material damages and economic losses are aspects covered under the warranty provisions. It is crucial to understand that failure to strictly observe the instructions detailed within this installation, operation, and maintenance manual could potentially lead to serious consequences, including personal injury and/or property damage. Furthermore, any such non-compliance or misuse of the product may unequivocally void the established product warranty. Therefore, users are strongly advised to meticulously read and fully comprehend all guidelines before installing, operating, or performing any maintenance on the pump. In the event that a warranty claim becomes necessary for your Goulds 3196 pump, the primary and essential step is to promptly contact your authorized ITT representative. They are equipped to guide you through the claims process and provide the necessary support.
CE, ATEX, and CSA Certification Details
This section outlines the critical certification details for Goulds 3196 i-FRAME pumps, ensuring compliance with international safety and operational standards. The manual confirms certifications for CE or CE ATEX, crucial for products intended for the European market and potentially explosive atmospheres. For ATEX-approved products, specific markings are provided, such as ‘Ex II 1 G’, indicating suitability for very high protection levels in zones where explosive atmospheres are continuously present or present for long periods. The temperature class for these units is T4, which signifies safe operation for ambient temperatures up to 100ºC. It is imperative that the product is used strictly in accordance with the approved motor data for Ex-approved applications to maintain safety integrity; Furthermore, the Goulds 3196 pumps also hold CSA certification, making them intrinsically safe for specific hazardous locations in North America. This includes Class I, Division 1, Groups A, B, C, D, and Class II, Division 1, Groups E, F, G. Users must verify that the pump’s code classifications are fully compatible with the intended installation environment. Operating equipment in an incompatible environment is strictly prohibited and requires immediate consultation with an ITT representative before proceeding. Adhering to these certifications is vital for safety and regulatory compliance.

Transportation and Storage
Proper transportation and storage are essential. Lift bare pumps using designated handles; base-mounted units require slings beneath the casing or base rails. Avoid certain lifting methods for heavy Polyshield systems to prevent damage. Follow storage guidelines, ensuring frost protection to prevent impeller freezing.
Approved Lifting Methods for Pump Handling
Safe and approved lifting methods are crucial to prevent personal injury and equipment damage during pump handling. For a bare pump, always utilize the designated lifting handles provided. This ensures a secure and balanced lift, minimizing risks associated with unstable loads. When dealing with a base-mounted pump assembly, the proper procedure involves using robust slings. These slings should be strategically placed under both the pump casing and the drive unit, or alternatively, beneath the sturdy base rails of the entire assembly. It is imperative to exercise caution and avoid certain lifting techniques, especially when handling a Polyshield ANSI Combo with the pump and motor already mounted. These integrated systems are not designed to withstand the considerable combined weight of the Polyshield components when lifted by methods intended for lighter configurations. Attempting such an improper lift could lead to severe equipment damage. Furthermore, when using straps for lifting, always ensure they are securely fastened at the frame adapter. This specific securing point is engineered to prevent any slippage of the strap during the lifting operation, thereby safeguarding against potential equipment damage and maintaining stability throughout the handling process. Adhering to these guidelines ensures safe and efficient movement of the pump.
Guidelines for Pump Storage and Frost Protection
Proper storage and frost protection are critical for Goulds 3196 pump longevity. The manual specifies frostproof conditions: when operating or fully immersed in liquid. However, lifting the pump from liquid into ambient temperatures below freezing poses a significant risk; the impeller and other internal components become highly susceptible to freezing damage, potentially compromising future operational reliability. Therefore, for any storage period, especially in environments prone to cold, it is essential to thoroughly drain all residual liquids from the pump casing and associated piping if dry storage is chosen to prevent ice formation. For prolonged storage, always maintain the pump in a clean, dry, adequately protected environment to safeguard its condition. Shielding it from adverse weather and extreme temperature shifts prevents corrosion and preserves mechanical integrity. Strict adherence to these guidelines ensures reliable performance and avoids costly repairs, significantly contributing to the pump’s extended service life. Consult the comprehensive manual for detailed long-term storage protocols.

Installation Procedures
Proper installation of the Goulds 3196 pump is crucial for optimal performance and safety. This section details essential steps, including meticulous foundation preparation, accurate baseplate leveling using shims or jackscrews, and precise pump, driver, and coupling alignment. Adherence ensures reliable operation and longevity.
Foundation Requirements and Baseplate Preparation
Ensuring a robust and correctly prepared foundation is paramount for the stable and efficient operation of the centrifugal pump. Before proceeding with the pump’s installation, meticulous attention must be given to the foundation requirements and the subsequent preparation of the baseplate. A solid, level, and vibration-dampening foundation is essential to prevent misalignment, reduce stress on components, and minimize potential noise transmission, especially if the pump’s location is overhead. Consultation with a noise specialist might be considered in such scenarios.
The preparation of the baseplate involves several critical steps to ensure its readiness for mounting on the foundation. Firstly, all attached equipment must be carefully removed from the baseplate. This allows for unobstructed access and thorough cleaning. Secondly, the entire underside of the baseplate needs to be cleaned completely, removing any debris, grease, or contaminants. This cleanliness is crucial for proper adhesion during grouting. Finally, if specified or deemed applicable for the installation environment, the underside of the baseplate should be coated with an epoxy primer. This protective layer enhances durability and corrosion resistance, ensuring a long service life for the pump assembly.
Baseplate Leveling: Shims, Wedges, Jackscrews, and Worksheet
Achieving precise baseplate leveling is a critical installation step, directly impacting the long-term reliability and operational efficiency of the pumping unit. Various methods are employed, including the strategic use of shims, wedges, and jackscrews, to ensure the baseplate is perfectly aligned. When installing the baseplate with shims or wedges, it is essential to maintain tight tolerances: a maximum difference of 3.2 mm (0.125 in.) lengthwise and 1.5 mm (0.059 in.) across is permitted. This meticulous leveling prevents undue stress on components and promotes smooth operation. A dedicated baseplate-leveling worksheet is provided to accurately record measurements during this process, aiding in systematic adjustment.
For installations utilizing jackscrews, the procedure involves carefully placing a machinist’s level lengthwise on one of the mounting pads and another across the ends of two pads. This dual measurement ensures comprehensive assessment of the baseplate’s flatness. Following this, the driver’s mounting pads must be checked for levelness, and adjustments made to the jackscrews and foundation bolts until the correct measurement of 0.0167 mm/m (0.002 in./ft) is achieved. Failure to meticulously follow these leveling instructions can lead to significant equipment damage or a notable decrease in performance, underscoring the importance of this phase.
Pump, Driver, and Coupling Installation with Alignment
The successful installation of the Goulds 3196 pump, its driver, and the coupling is paramount for ensuring long-term operational integrity and efficiency. This phase involves meticulous attention to alignment, which directly impacts bearing life, seal performance, and overall system reliability. Following the secure mounting of the baseplate, the pump and driver units are carefully positioned. The coupling, which transmits power between the driver and the pump, must be installed precisely, adhering to specific manufacturer guidelines to prevent angular and parallel misalignment.
Crucially, both initial and ongoing alignment checks are required. The manual emphasizes the importance of pump-to-driver alignment instructions, as even minor misalignments can lead to premature wear and increased energy consumption. After the initial installation, a “final alignment” or “hot alignment” check is performed subsequent to the pump’s first run. This critical step ensures that correct alignment is maintained once both the pump and driver reach their normal operating temperatures, as thermal expansion can alter initial cold alignment settings. Furthermore, periodic alignment checks should be incorporated into routine plant operating procedures.
When conducting alignment checks, specific permitted indicator values must be adhered to. These values guide adjustments, allowing for precise repositioning of the driver before any alignment corrections are made. It is also vital to re-check the alignment after any mechanical adjustments to correct potential misalignments introduced during maintenance or servicing. This comprehensive approach to installation and alignment safeguards the equipment, minimizes downtime, and extends the operational life of the Goulds 3196 pump system.